Shipping Weight : 1 Kg
RTD excitation current : 200µA nominal
Common mode rejection : 120dB for 240V at 50Hz or 60Hz
Series mode rejection : 40dB for 50Hz or 60Hz
Response time : Typical 500 ms
Safety drive on sensor failure : Upscale, downscale, or off
Cold junction compensation error : ≤ 1.0°C
MTL4573 MTL Instruments TEMPERATURE CONVERTER THC Or RTD Input
The MTL4573 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safe-area load. Software selectable features include linearisation, ranging,monitoring, testing and tagging for all thermocouple types and 2-, 3-or 4-wire RTDs. (For thermocouple applications the HAZ-CJC plug on terminals 1–3 includes an integral CJC sensor). Configuration is carried out using a personal computer.
SPECIFICATION
 See also common specification
 • Number of channels
      One
 • Location of signal source
      Zone 0, IIC, Hazardous area
      Division 1, Groups A-D, hazardous location
 • RTD excitation current
      200µA nominal
 • Cold junction compensation, THC input
      Selectable ON or OFF
 • Cold junction compensation error
      ≤ 1.0°C
 • Common mode rejection
      120dB for 240V at 50Hz or 60Hz
 • Series mode rejection
      40dB for 50Hz or 60Hz
 • Calibration accuracy (at 20°C)
   (includes hysteresis, non-linearity and repeatability)
      Inputs:
         mV/THC:            ± 15µV or ± 0.05% of input value
                                    (whichever is greater)
         Pt 100 - RTD:     ± 80mΩ
      Output:                  ± 11µA
 • Temperature drift (typical)
      Inputs:
         mV/THC:            ± 0.003% of input value/°C
         Pt 100 - RTD:     ± 7mΩ/°C
      Output:                  ± 0.6µA/°C
 • Example of calibration accuracy and temperature drift
   (RTD input)
      Span:                           250Ω
      Accuracy:                    ± (0.08/250 + 11/16000) x 100%
                                              = 0.1% of span
      Temperature drift:       ± (0.007/250 x 16000 + 0.6) µA/°C
                                              = ±1.0µA/°C
 • Safety drive on sensor failure
      Upscale, downscale, or off
 • Early burnout
      Early burnout detection for thermocouples (when selected)
      EBD indicated when loop resistance increase is > 50Ω
 • Output range
      4 to 20mA nominal into 600Ω max.
      Out of range characteristic - MTL or NAMUR NE43
 • Maximum lead resistance (THC)
      600Ω with safety drive on sensor failure enabled.
      >10kΩ with safety drive on sensor failure disabled
 • Response time
      Typical 500 ms
 • LED indicator
      Green: EBD alarm indication, power and status indication
      Yellow: alarm indication
 • Maximum current consumption (with 20mA signal)
      50mA at 24V
 • Power dissipation within unit (with 20mA signal)
      1.2W at 24V
 • Safety description
      Refer to certificate for parameters. Um=253V rms or dc
 • Configurator
      A personal computer running MTL PCS45 software with a PCL45USB serial interface.
 
   
  
Related Models:
| HCU16 | MTL5521 | 
| HCU3700 | MTL5522 | 
| HM64RIB20-1.0 | MTL5531 | 
| HM64RIB20-1.5 | MTL5532 | 
| HMM64 | MTL5541 | 
| HMRIB16-1.0 | MTL5541S | 
| HMS64 | MTL5544 | 
| HTP-SC32 | MTL5544D | 
| MTL4044D | MTL5546 | 
| MTL4511 | MTL5546Y | 
| MTL4516 | MTL5561 | 
| MTL4516C | MTL5573 | 
| MTL4521 | MTL5575 | 
| MTL4541 | MTL5582B | 
| MTL4541 | MTL7728+ | 
| MTL4544 | MTL7756AC | 
| MTL4544D | MTL7760AC | 
| MTL4546Y | MTL7761PAC | 
| MTL4549Y | MTL7765AC | 
| MTL4573 | MTL7787+ | 
| MTL4575 | MTL7787P+ | 
| MTL4646Y | MTLCPS16 | 
| MTL4850 | NJ5-18GK-N | 
| MTL4851 | SD150X | 
| MTL4852 | SD32 | 
| MTL5018 | SD32X | 
| MTL5032 | SDRTD | 
| MTL5042 | SLP32D | 
| MTL5044 | TP48-3-I-NDI | 
| MTL5049 | TP48-3-N-NDI | 
| MTL5511 | TP48-4-I-NDI | 
| MTL5514D | TP48-4-N-NDI | 
| MTL5516 | TP48-N-NDI | 
| MTL5516C | ZB24571 | 
Company Introduction:
Achievers Automtation Limited deals with a complete range of industrial automation components and instruments with more than 12 years’ experience, and always try best to provide quality goods and timely services to our valued customers from over 45 countries worldwide.
Achievers serves the Oil & Gas industries, EPC contractors, System Integrators and other industrial automation and process control companies worldwide. The industries we serve include Oil & Gas, Chemical, Petrochemical, Mining, Energy & Utilities, Pharmaceuticals, Electronics, Food and etc.
The company provides a diversified range of products to meet any process control and automation challenges in the industry. We stock and distribute pressure & temperature transmitters, level controller & transmitters, temperature probes, flowmeter, vibration monitoring devices, chart recorders, sensors, PLC, DCS, HMI, measuring instruments and other field instruments.
Below are the TOP BRANDS we handle in the past 12 years:
Bently Nevada 3500 Vibration Monitoring System&3300 Proximity Probes, Sensors & Transducer Systems
ALLEN BRADLEY Industrial Control Products
Pepperl-Fuchs Industrial Sensors & Isolated Barrier
MTL Instruments Isolated Barrier
Endress+Hauser Flow, Level, Liquid Analysis Instrument
YOKOGAWA DCS & Field Instruments & Process Analyzers
Rosemount Analytical Products
ASCO Solenoid Valves
FISHER Valve&Positioner
IFM Sensors & Controllers
ABB V18345 Valve Positioner
ABB Bailey Infi 90 and Net 90 Modules
FISHER DLC3100 Digital Level Controller
TELEDYNE Oxygen Sensor & Fuel Cell
HONEYWELL Switches & Transmitter
VEGA Level Measurement Products
AUMA Electric Actuators and Gearboxes
SMC Controls, process, and Industrial products
SICK Industrial Sensors
FESTO Pneumatic & Electric Automation Products
YASKAWA Industrial Ac Drives
BECKOFF Controllers & I/O Modules
BALLUFF Linear Position Sensors
SCHMERSAL Safety switches & Safety Systems
 FAQ of Achievers
 Q:Are the Products Genuine OEM Units?
 A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
 Q:How will you arrange shipment?
 A: We can arrange shipment based on your request. We have cooperated forwader who can arrange shipment via FedEx, DHL,TNT with good price.
 Q:What is the warranty of goods?
 A: One-year Warranty.
|   | 
| MTL4573 MTL Instruments Temperature Converter THC RTD Input Number Of Channels One Images | 
 MTL5561 MTL Instruments MTL Fire & Smoke Detector Interface
                                                                                    
                        
                        
                        
                                                            MTL5561 MTL Instruments MTL Fire & Smoke Detector Interface
                                                    
                        
                     MTL5576-RTD MTL Instruments | 2ch Temperature converter, RTD
                                                                                    
                        
                        
                        
                                                            MTL5576-RTD MTL Instruments | 2ch Temperature converter, RTD
                                                    
                        
                     MTL5576-THC MTL Instruments Temperature Converter Number Of Channels Two
                                                                                    
                        
                        
                        
                                                            MTL5576-THC MTL Instruments Temperature Converter Number Of Channels Two
                                                    
                        
                     MTL5522 MTL Instruments Solenoid / Alarm Driver Number of channels One
                                                                                    
                        
                        
                        
                                                            MTL5522 MTL Instruments Solenoid / Alarm Driver Number of channels One
                                                    
                        
                     MTL5582B MTL Instruments Resistance Isolator To Repeat RTD Signals
                                                                                    
                        
                        
                        
                                                            MTL5582B MTL Instruments Resistance Isolator To Repeat RTD Signals
                                                    
                        
                     HCU16 MTL Instrument HART Connection Unit Accuracy (HCU16-P250 only) 250Ω ±0.05%
                                                                                    
                        
                        
                        
                                                            HCU16 MTL Instrument HART Connection Unit Accuracy (HCU16-P250 only) 250Ω ±0.05%
                                                    
                        
                     MTL7778AC MTL Instruments Shunt-diode Safety Barrier 10.5cm x 1.26cm x 9cm
                                                                                    
                        
                        
                        
                                                            MTL7778AC MTL Instruments Shunt-diode Safety Barrier 10.5cm x 1.26cm x 9cm
                                                    
                        
                     MTL5514 MTL Switch/Proximity Detector Interface Response time 10ms maximum
                                                                                    
                        
                        
                        
                                                            MTL5514 MTL Switch/Proximity Detector Interface Response time 10ms maximum
                                                    
                        
                     MTL4041B MTL Instruments Repeater Power Supply Number Of Channels One
                                                                                    
                        
                        
                        
                                                            MTL4041B MTL Instruments Repeater Power Supply Number Of Channels One
                                                    
                        
                     MTL5044 MTL Instruments Repeater Power Supply Supply voltage 20 to 35V dc
                                                                                    
                        
                        
                        
                                                            MTL5044 MTL Instruments Repeater Power Supply Supply voltage 20 to 35V dc